T trigger





| Vector | C | ST |
in the palette on the schematic
The block implements a countable trigger model that changes its dependency state based on the countable input type:
  • by the front – when changing the value at the synchronizing input from 0 to 1;
  • by the drop – when changing the value at the synchronizing input from 1 to 0;
  • by the front and drop – in case of any change in the value at the synchronizing input;
  • by level – when a logical unit is supplied to the synchronizing input (the state of the trigger will change at each integration step).

Inputs

  • T – countable input port of the trigger.

Outputs

  • out – trigger output port;
  • Yinv – the inverse output port (optionally added in the block properties).

Properties

  • Initial conditions – initial values of the output logic signal;
  • Counting input type – counting input triggering condition;
  • Add inverse output – indicates the presence of an inverse output.

Parameters

none