TR trigger

| Vectorized | C |
in the palette on the schematic

Implements a reset-priority TR trigger model with the countable input. If at least one of the inputs R or S is supplied with a logical unit, then the trigger works as a priority-reset RS-trigger:

where y(t) is the output signal of the block, xS(t), xR(t) is the first and third input signals of the block (from English: Set and Reset).

If a logic zero is applied to both inputs R and S, then the trigger acts as a counting trigger that changes its dependency state based on the type of counting input:

Input ports

  • S – the input port for setting the trigger;
  • T – countable input port of the trigger;
  • R – the input port for resetting the trigger.

Output ports

  • out – trigger output port;
  • Yinv – the inverse output port (optionally added in the block properties).

Properties

  • Initial conditions – initial values of the output logic signal;
  • Counting input type – counting input triggering condition;
  • Add inverse output – indicates the presence of an inverse output.

Parameters

none