Translatory damper with variable factor





| C |
in the palette on the schematic

The block is designed to simulate a linear translatory damper with the variable damping factor

The damper relative speed v in m/s is determined by the formula:

where vC and vR – linear speeds at ports "C" and "R", respectively, m/s.

The damping force is determined by the formula:



where:
  • FC and FC – forces applied to ports "C" and "R", respectively, N
  • D – defined damping factor, N/m·s
  • Dmin – minimum damping factor, N/m·s

Inputs

Name Description Connection line type
D Defined damping factor Mathematical
C Port for connecting a conditionally fixed case (case) Translatory mechanics
R Port for connecting a conditionally movable rod (rod) Translatory mechanics

Outputs

None.

Properties

Name Parameter Description By default Data type
Minimum damping factor, N·s/m Dmin Minimum damping factor 0 Вещественное

Parameters

Name Parameter Description Data type
Speed differential, m/s V Relative damper elongation speed Вещественное
Damping force, N F Damping force Вещественное
Power of damping force, W Q Power of damping force Вещественное

Examples

Examples of block application: