Translatory damper with variable factor
![]() |
![]() |
| C | |
| in the palette | on the schematic |
The block is designed to simulate a linear translatory damper with the variable damping factor
The damper relative speed v in m/s is determined by the formula:


where vC and vR – linear speeds at ports "C" and "R", respectively, m/s.
The damping force is determined by the formula:




where:
- FC and FC – forces applied to ports "C" and "R", respectively, N
- D – defined damping factor, N/m·s
- Dmin – minimum damping factor, N/m·s
Inputs
| Name | Description | Connection line type |
|---|---|---|
| D | Defined damping factor | Mathematical |
| C | Port for connecting a conditionally fixed case (case) | Translatory mechanics |
| R | Port for connecting a conditionally movable rod (rod) | Translatory mechanics |
Outputs
None.
Properties
| Name | Parameter | Description | By default | Data type |
|---|---|---|---|---|
| Minimum damping factor, N·s/m | Dmin | Minimum damping factor | 0 | Вещественное |
Parameters
| Name | Parameter | Description | Data type |
|---|---|---|---|
| Speed differential, m/s | V | Relative damper elongation speed | Вещественное |
| Damping force, N | F | Damping force | Вещественное |
| Power of damping force, W | Q | Power of damping force | Вещественное |
Examples
Examples of block application: