The block is a relay link with a deadband. The block forms at the output a logic 1 if the input signal has exceeded the setpoint value, or logic 0 if the signal has become less than the setpoint (taking into account the return zone, if it is set to non-zero):

where x(t) is the input signal; y(t) is the output signal; a, x0 is the value of the return zone and the setpoint. The block is a submodel. To view the structure of the algorithm, right-click Actions → Enter to the submodel.

Входные порты

  • signal - input signal.

Выходные порты

  • releay output - output relay signal.

Свойства

  • Setpoint - setpoint value with which the input signal is compared. In other words, the upper switching limit of the relay link.
  • Return zone - a value that is subtracted from the setpoint to form the lower switching limit of the relay link.

Параметры